Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. anestesiol ; 69(2): 115-121, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1003401

ABSTRACT

Abstract Background and objectives: Preoperative fasting may lead to undesirable effects in the surgical patient in whom there is a stimulus to ingesting clear liquids until 2 hours before anesthesia. The aim of this study was to evaluate the gastric emptying of two different solutions using ultrasound. Methods: In a prospective, randomized, blind study, 34 healthy volunteers ingested 200 mL of two solutions without residues in two steps: an isotonic solution with carbohydrates, electrolytes, osmolarity of 292 mOsm.L-1, and 36 kcal; and other nutritional supplementation with carbohydrates, proteins, electrolytes, osmolarity of 680 mO.L-1, and 300 kcal. After 2 hours, a gastric ultrasound was performed to assess the antrum area and gastric volume, and the relation of gastric volume to weight (vol.w-1), whose value above 1.5 mL.kg-1 was considered a risk for bronchoaspiration. A p-value <0.05 was considered statistically significant. Results: There was a significant difference between all parameters evaluated 2 hours after the ingestion of nutritional supplementation compared to fasting. The same occurred when the parameters between isotonic solution and nutritional supplementation were compared 2 hours after ingestion. Only one patient had vol.w-1 <1.5 mL.kg-1 2 hours after ingestion of nutritional supplementation; and only one had vol.w-1 >1.5 mL.kg-1 after ingestion of isotonic solution. Conclusion: This study demonstrated that gastric emptying of equal volumes of different solutions depends on their constitution. Those with high caloric and high osmolarity, and with proteins present, 2 hours after ingestion, increased the gastric volumes, which is compatible with the risk of gastric aspiration.


Resumo Justificativa e objetivos: O jejum pré-operatório pode levar a efeitos indesejáveis no paciente cirúrgico, em que há um estimulo à ingestão de líquidos sem resíduos até 2 horas antes da anestesia. O objetivo deste estudo foi avaliar o esvaziamento gástrico de duas soluções diferentes por meio da ultrassonografia. Métodos: Em um estudo prospectivo, randomizado, cego, 34 voluntários saudáveis ingeriram 200 mL de duas soluções sem resíduos, em duas etapas: uma solução isotônica com carboidratos, eletrólitos, osmolaridade de 292 mOsm.L-1 e 36 kcal; e outra suplementação nutricional, com carboidratos, proteínas, eletrólitos, osmolaridade de 680 mOs.L-1 e 300 kcal. Após 2 horas, fez-se ultrassonografia gástrica com avaliação da área do antro e volume gástrico e relação do volume gástrico sobre o peso (vol.p-1), cujo valor acima de 1,5 mL.kg-1 foi considerado risco para broncoaspiração. Considerou-se p< 0,05 como estatisticamente significativo. Resultados: Houve diferença significativa entre todos os parâmetros avaliados 2 horas após a ingestão de suplementação nutricional em relação ao jejum. O mesmo ocorreu quando foram comparados os parâmetros entre solução isotônica e suplementação nutricional 2 horas após a ingestão. Apenas um paciente apresentou vol.p-1< 1,5 mL.kg-1 2 horas após a ingestão de suplementação nutricional; e apenas um apresentou vol.p-1 > 1,5 mL.kg-1, após a ingestão de solução isotônica. Conclusão: Este estudo demonstrou que o esvaziamento gástrico de volumes iguais de diferentes soluções depende de sua constituição. Aqueles com alto valor calórico e alta osmolaridade, e com proteínas presentes, 2 horas após a ingestão, aumentaram os volumes gástricos, compatíveis com o risco de aspiração gástrica.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Ultrasonography/methods , Dietary Supplements , Gastric Emptying/physiology , Isotonic Solutions/administration & dosage , Osmolar Concentration , Stomach/diagnostic imaging , Energy Intake/physiology , Carbohydrates/administration & dosage , Proteins/administration & dosage , Prospective Studies , Fasting/psychology , Electrolytes/administration & dosage
2.
Rev. bras. anestesiol ; 67(4): 376-382, July-aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-897739

ABSTRACT

Abstract Background and objectives: The current preoperative fasting guidelines allow fluid intake up to 2 h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2 h after ingestion of 200 and 500 mL of isotonic solution, by means of ultrasound assessment. Method: Eighty volunteers underwent gastric ultrasound at three times: after 8 h of fasting; 2 h after ingestion of 200 mL isotonic saline, followed by the first scan; and on another day, 2 h after ingestion of 500 mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants' gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value < 0.05 was considered significant). Results: There was no difference in quantitative variables at measurement times (p > 0.05). Five volunteers (6.25%) had a volume/weight over 1.5 mL kg-1 at fasting and 2 h after ingestion of 200 mL and 6 (7.5%) after 500 mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500 mL (18.7%), although not statistically significant. Conclusion: Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2 h after ingestion of 200 mL or 500 mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500 mL isotonic solution.


Resumo Justificativa e objetivos: As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500 ml de solução isotônica. Método: Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8 horas; 2 horas após a ingestão de 200 ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2 horas após a ingestão de 500 ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p < 0,05. Resultados: Não houve diferença nas variáveis quantitativas nos três momentos estudados (p > 0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5 ml.kg-1 em jejum e 2 horas após a ingestão de 200 ml e seis (7,5%) após 500 ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500 ml (18,7%), embora sem significância estatística. Conclusão: O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2 horas após a ingestão de 200 ml ou de 500 ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500 ml de solução isotônica.


Subject(s)
Humans , Male , Female , Adult , Stomach/anatomy & histology , Stomach/diagnostic imaging , Isotonic Solutions/administration & dosage , Organ Size , Stomach/physiology , Cross-Sectional Studies , Prospective Studies , Ultrasonography , Eating
3.
J. bras. econ. saúde (Impr.) ; 8(3): 216-220, 10/02/2017.
Article in Portuguese | ECOS, LILACS | ID: biblio-831902

ABSTRACT

Objetivo: O objetivo deste estudo foi estimar a prevalência de risco de broncoaspiração e a verificação do custo-efetividade da aplicação de protocolo preventivo. Métodos: Realizou-se estudo transversal de base hospitalar com amostra aleatória simples, seguido de análise estatística de associação e econômica do tipo árvore de decisão e custo-efetividade. Resultados: Verificou-se que a prevalência de risco de broncoaspiração é alta em hospitais gerais de grande porte, com a magnitude de 56%, e que a aplicação de protocolo preventivo com avaliação precoce de fonoaudiologista é custo-efetiva, com ganho de quase R$ 900,00 por internação hospitalar, além de redução de 0,15 dia de internação também por paciente, com razão de custo-efetividade incremental de economia de R$ 5.607,83. Conclusão: Conclui-se que a adoção de programa preventivo com a participação de fonoaudiólogos é altamente custo-efetiva.


Objective: The objective of this study was to estimate the prevalence of risk of aspiration and analysis of the cost effectiveness of the implementation of a preventive protocol. Methods: A cross-sectional study of hospital base with simple random sample, followed by statistical analysis of association and economic cost-effectiveness analysis using a decision tree. Results: It was found that the prevalence of risk of aspiration is high in general hospitals, with the magnitude of 56%, and that the implementation of preventive protocol with early evaluation of speech therapy is cost effective, with a gain of almost R$ 900.00 per hospitalization, as well as a reduction of 0.15 days of hospitalization also per patient, with incremental cost-effectiveness ratio of R$ 5,607.83 of economy. Conclusion: It is concluded that the adoption of preventive program with participation of speech therapy is highly cost-effective.


Subject(s)
Humans , Epidemiology , Cost-Benefit Analysis , Disease Prevention
SELECTION OF CITATIONS
SEARCH DETAIL